Advanced solar pumping solution with AC/DC input, WiFi monitoring, and full motor protection for 24/7 operation
| Parameter | Specification |
|---|---|
| MPPT Efficiency | > 99.6% |
| Output Frequency Range | 0 - 600Hz |
| Motor Types Supported | PMSM, Asynchronous motors |
| Input Voltage Range | AC/DC input with seamless switching |
| Protection Rating | IP20 (IP55/IP65 options available) |
| Operating Temperature | -25°C to +60°C |
| Control Modes | VF control, Vector control |
| Communication | WiFi, RS485, Modbus compatible |
2S series models are designed for 220VAC pumps with MPPT voltage range of 260-375V. These models are suitable for smaller to medium-sized pumping applications.
Power: 0.75KW
Rated Current: 3.8A
MPPT Voltage: 260-375V
Power: 1.5KW
Rated Current: 7A
MPPT Voltage: 260-375V
Power: 2.2KW
Rated Current: 10A
MPPT Voltage: 260-375V
Power: 4.0KW
Rated Current: 17A
MPPT Voltage: 260-375V
4T series models are designed for 380VAC pumps with MPPT voltage range of 486-750V. These models cover a wide range of power requirements from 0.75KW to 400KW.
| Model | Rated Current | Output Voltage | Applicable Pumps | MPPT Voltage |
|---|---|---|---|---|
| 11PV-0K7GB-4T-M | 2.3A | 0-380V | 0.75KW | 486 to 750V |
| 11PV-1K5GB-4T-M | 3.8A | 0-380V | 1.5KW | 486 to 750V |
| 11PV-2K2GB-4T-M | 5.1A | 0-380V | 2.2KW | 486 to 750V |
| 11PV-0K7GB-4T | 2.3A | 0-380V | 0.75KW | 486 to 750V |
| 11PV-1K5GB-4T | 3.8A | 0-380V | 1.5KW | 486 to 750V |
| 11PV-2K2GB-4T | 5.1A | 0-380V | 2.2KW | 486 to 750V |
| 11PV-4K0GB-4T | 10A | 0-380V | 4.0KW | 486 to 750V |
| 11PV-5K5GB-4T | 13A | 0-380V | 5.5KW | 486 to 750V |
| 11PV-7K5GB-4T | 17A | 0-380V | 7.5KW | 486 to 750V |
| 11PV-011GB-4T | 25A | 0-380V | 11KW | 486 to 750V |
| 11PV-015GB-4T | 32A | 0-380V | 15KW | 486 to 750V |
| 11PV-018GB-4T | 37A | 0-380V | 18KW | 486 to 750V |
| 11PV-022GB-4T | 45A | 0-380V | 22KW | 486 to 750V |
| 11PV-030G-4T | 60A | 0-380V | 30KW | 486 to 750V |
| 11PV-037G-4T | 75A | 0-380V | 37KW | 486 to 750V |
| 11PV-045G-4T | 91A | 0-380V | 45KW | 486 to 750V |
| 11PV-055G-4T | 110A | 0-380V | 55KW | 486 to 750V |
| 11PV-075G-4T | 150A | 0-380V | 75KW | 486 to 750V |
| 11PV-090G-4T | 180A | 0-380V | 90KW | 486 to 750V |
| 11PV-110G-4T | 220A | 0-380V | 110KW | 486 to 750V |
| 11PV-132G-4T | 260A | 0-380V | 132KW | 486 to 750V |
| 11PV-160G-4T | 320A | 0-380V | 160KW | 486 to 750V |
| 11PV-185G-4T | 340A | 0-380V | 185KW | 486 to 750V |
| 11PV-200G-4T | 380A | 0-380V | 200KW | 486 to 750V |
| 11PV-220G-4T | 415A | 0-380V | 220KW | 486 to 750V |
| 11PV-250G-4T | 470A | 0-380V | 250KW | 486 to 750V |
| 11PV-280G-4T | 520A | 0-380V | 280KW | 486 to 750V |
| 11PV-315G-4T | 585A | 0-380V | 315KW | 486 to 750V |
| 11PV-355G-4T | 650A | 0-380V | 355KW | 486 to 750V |
| 11PV-400G-4T | 725A | 0-380V | 400KW | 486 to 750V |
Note: IP55 high protection class models up to 22KW are available. OEM steel housing design for 0.75KW to 22KW models are optional.
Ideal for various water pumping requirements across multiple sectors:
| Pump Voltage | Inverter Model | Recommended Vmp | Recommended Voc | Solar Array Power |
|---|---|---|---|---|
| 110VAC | 1S | 130VDC | 156VDC | ≥1.3-2.0 × Pump Power |
| 220VAC | 2S | 310VDC | 372VDC | ≥1.3-2.0 × Pump Power |
| 380VAC | 4T | 540VDC | 648VDC | ≥1.3-2.0 × Pump Power |
| 480VAC | 4T | 677VDC | 812VDC | ≥1.3-2.0 × Pump Power |
| Parameter | Function | Setting Range |
|---|---|---|
| PE-00 | Solar Pump Control Mode | 0: Disable, 1: MPPT1 (High Efficiency), 2: MPPT2 (High Stability) |
| PE-01 | Solar Pump Control Options | Vmp mode, Voc detection, Auto running |
| PE-16 | Sleep Voltage Threshold | 0.0-1000.0V |
| PE-17 | Wake Up Voltage Threshold | 0.0-1000.0V |
| PE-19 | Stop Frequency (Low Speed) | 0.00-300.00Hz |
| PE-22 | Dry Run Protection Current | 0.0-999.9A |
| PE-31 | Water Tank Level Detection | Digital/Analog sensor options |
Contact our technical team for customized solar pumping solutions and expert guidance
Request Technical ConsultationThanks for subscribing!
This email has been registered!